Skip to content
senn-techsenn-tech
Back to blog
Storage
Storage, backup and replication2026-11-26· By Franz Senn

VROC on AMD EPYC: the first release is planned for February 2027, with Linux and mirrored boot drives

Graid Technology announced on 16 November 2026 that it is bringing VROC to systems with AMD EPYC. The first release is planned for February 2027 and brings Linux with RAID 1 for boot drives. The sentence that is the actual reason this is news: no dedicated RAID controller is required.

VROC stands for Virtual RAID on CPU and means RAID that runs directly on the processor, without a RAID card. The NVMe drives talk over the CPU's PCIe root complex, with no board in a slot in between. Intel handed VROC's rights to Graid Technology in a licence agreement in 2025, and since 17 November 2025 Graid serves existing and new customers. The first date for AMD EPYC is February 2027, with Linux and RAID 1 for boot drives.

What Graid announced for 2027

The announcement is a sequence, not a feature set. We kept the structure Graid itself uses.

WhenAnnouncedWhat is actually fixed
February 2027Linux, RAID 1 as a mirror for boot drivesdate and scope named, release pending
First half of 2027RAID 0, RAID 5, RAID 10; drive status LED management; hot swapping while runningdirection named, no date
Second half of 2027out-of-band management; Windows; SATA; self-encrypting drives, including hot swapping of those drivesdirection named, no date

Graid qualifies this itself: features may vary by platform and release, all plans and timelines are subject to change. The product page for Intel Xeon 6 lists bootable RAID in levels 0, 1, 5 and 10, RAID 1 and 5 under VMware ESXi as planned, and a 24-month roadmap with GPUDirect Storage, OpenBMC and PCIe Generation 6, plus up to about 29 GB/s throughput and about 6 million read operations per second, a vendor figure with no stated measurement setup.

Why this is news at all

The point sits a little over a year back and is called Intel. On 17 November 2025 Graid announced the completed agreement with Intel: the rights to license, market, sell and develop Intel VROC pass to Graid. Intel's own support notice carries the dates: new enquiries through Intel's normal channels stopped on 1 November 2025, and Graid has served existing and future customers since 17 November 2025. The AMD EPYC announcement of 16 November 2026, just under a year after that agreement, is the first new feature since the transition that we have seen planned in public.

Anyone with one of these machines in the rack experienced that as an operational change: a component of the storage layer changed owner without anything changing in the hardware. That is why the AMD announcement is the second half of the same story. VROC is no longer one CPU maker's hardware-adjacent RAID option but an independent vendor's product that can choose platforms. The product page already carries that claim in its own words ("Intel Xeon 6 and Beyond"), and the announcement names AMD EPYC as the start for further server and edge platforms.

Graid reasons that storage should not complicate the choice of processor and names one RAID platform across two architectures. That benefit is real but tied to one condition: drive management and fault reporting have to come from a single source, otherwise you end up with two tools.

The part that concerns us: boot drives

RAID 1 on two boot disks is the protection a hypervisor node needs most often and solves least cleanly. We measured nine Linux systems in our estate on 26 November 2026, two physical hosts and seven guests.

What we measuredResultReading
Systems with a kernel RAID array (/proc/mdstat)0 of 9no array for boot or root
Kernel module md_mod loaded0 of 9the capability is there, unused
The two physical hostsone NVMe disk each, once XFS written directly on the partition, once a logical volume over exactly one diskRAID absent, LVM does not replace it
The seven guestsroot on a virtio disk, three of them via logical volumes, none with RAIDredundancy sits below the guest
Boot areaseparate boot partition on one of the two physical hosts only, EFI system partition on bothtwo layouts, no shared rule
The layer under the guestsstorage configuration of the six nodes, read over the management API: each carries the same block storage entry and three backup server entriesplanned replication and backup, no outage proof
Processorall nine report AuthenticAMD; the two physical hosts report EPYC 7502 and EPYC 8024P, the guests two further strings (EPYC 7F52, Ryzen 9 7945HX)a hypervisor sets the string for guests; which models Graid means is not in the announcement
Root disks by layout, nine Linux systemsSingle disk device, no LVM5Logical volume (LVM)4RAID array006
Counted on 26 November 2026 across two physical hosts and seven guests. The zero is the finding: no system boots from a RAID array. (source: Own measurement, /proc/mdstat, lsblk and lvs, 26 November 2026)

The table in one sentence: our redundancy is replication under the guests plus backups as configured there, never proven in an outage, and nothing protects boot drives at drive level. When a boot SSD dies, the node returns when somebody rebuilds it. That is an operating decision, not a technical limit, and the same case Graid addresses for February 2027. The difference is not intent but precondition: VROC assumes two NVMe drives on the PCIe root complex of a real server, and our two hosts each hold one disk.

What stays open

Only the measured systems count. Nine systems means two physical hosts and seven guests. The two physical hosts are our inference machines, not the nodes of the virtualisation cluster; those six nodes were not reachable over SSH from this machine, so their own boot area is unmeasured. The row about the layer under the guests is storage configuration read from the management API. The disk layout table speaks about these nine systems, not the whole estate.

There is no price. The announcement carries no price, no licence model, no evaluation programme. For a feature the server manufacturer integrates, we assume the purchase price sits with the manufacturer rather than Graid; nothing we could find documents it.

No generation named. Graid names no minimum processor and no platform list for AMD EPYC. Our two physical hosts are an EPYC 7502 (Rome) and an EPYC 8024P (Sienna); whether models like these are meant is in no line we could find.

The number is a vendor figure. The up to about 29 GB/s and about 6 million reads per second on the product page come with no stated measurement setup. We have neither an Intel Xeon 6 machine nor its drive choice in the rack, so we cannot re-measure it.

No outage proof. The announcement says what the feature does, not how often it has prevented an outage. We have no figure for that.

The support transition is a contract, not a quality statement. That Graid has served VROC since November 2025 is provable through Intel. How support and firmware maintenance develop, will show later.

What it means

The announcement is less a product than a change of status. A hardware-adjacent option of one CPU maker becomes a product with platform choice, and the first market it serves is not speed but whether the operating system survives a dying boot SSD. Anyone buying AMD EPYC with NVMe boot drives needs an answer to that by February 2027, by hand or with a controller. Anyone running VROC should check the support situation after the transition once.

For us the boot drive of the virtualisation nodes belongs in the check at the next maintenance window, together with the question of whether a rebuild can be automated. Anyone who wants to measure their own position needs four commands: cat /proc/mdstat, lsblk -o NAME,SIZE,TYPE,MOUNTPOINT, lvs and zpool status. Ours reads: no array, no mirror, replication one layer down. How we built that layer is in storage journey part 2: Vitastor; how an external file server hands disks to Proxmox guests is shown by the TrueNAS plugin for Proxmox. More measurements on our own storage hardware appear under storage and backup, and for anyone who does not want to run that comparison themselves, it is part of what we do in server and storage decisions.

Further Reading

Questions?
What is VROC in one sentence?+

VROC stands for Virtual RAID on CPU and is RAID that runs directly on the processor without its own RAID card. The NVMe drives hang off the CPU's PCIe root complex. Intel handed the rights to Graid Technology under a licence agreement in 2025, read from Intel's support-transition notice, a page dated as last reviewed on 17 November 2025.

What does the first version for AMD EPYC do?+

Linux and RAID 1 as a mirror for boot drives, meaning drives carrying the operating system. That is the announcement of 16 November 2026 with a planned date of February 2027. RAID 0, 5 and 10, drive status LED management and hot-plug are named for the first half of 2027, Windows, SATA and self-encrypting drives for the second.

Does that replace a RAID card?+

For the announced profile, yes, per Graid's own statement: no dedicated RAID controller is required. The price is a bond to CPU vendor and operating system, since RAID 1 works only under Linux first and Windows is planned for the second half of 2027.

Do our boot drives have a mirror today?+

Not at drive level. Among the nine systems we measured on 26 November 2026, not one has a RAID array, and the kernel module for it is loaded on none of them. The boot areas of our six virtualisation nodes are unmeasured. Our redundancy comes from the layer under the guests and from backups.